Productdetails:
|
Materiaal: | vezelpijp | kleur: | Beige |
---|---|---|---|
Nominale spanning: | 600Vdc | Geschatte Stroom: | 1000A |
Brekende Capaciteit: | 50kA | Norm: | IEC60269, UL248 |
Gebruik: | Overbelastingsbescherming, het Laden Post | Sleutelwoord: | NH Type HRC Zekering |
Hoog licht: | 50kA NH Type HRC Zekering,UL248 NH Type HRC Zekering,Thermische hrczekering 100 ampère |
NH Type HRC Thermische 100a 250a 300a Zekering van Zekerings de Veelvoudige Modellen en Zekeringsbasis
Materiaal:
Noumenon: vezelpijp
Spelden: Legering
Eigenschappen:
Hoge Brekende Capaciteitszekering
Vele soorten Hoge Brekende Capaciteit smelten
Huidige classificatie: 6A-630A
Voltageclassificatie: AC500V/DC440V of lager
Brekende capaciteit: AC500V/120kA DC440V/50kA
Productpresentatie:
Nominale spanning |
AC500V/DC440V |
Typebescherming |
AR |
Geschatte Stroom | 6A-630A |
Brekende Capaciteit |
AC500V/120kA DC440V/50kA (tijdsconstante 15-20ms) |
Voldoe aan het Vereiste |
UL248-13, IEC60269.4 De EU en Rosh-Richtlijn |
Opmerkingen |
Algemene afmetingen van het product (mm)
MNH3-00 | Mnh3-1 | Mnh3-2 | Mnh3-3 | |
a1 | 7.85±1.5 | 135±2.5 | 150±2.5 | 150±2.5 |
a20-5 | 54 | 72 | 72 | 72 |
a3 | 45±1.5 | 62±2.5 | 62±2.5 | 62±2.5 |
(Maximum) F | 15 | 15 | 15 | 18 |
b±0.2 | 15 | 20 | 25 | 32 |
e1±3 | 57 | 62 | 72 | 82 |
e2 | 29±1 | 48±2 | 58±2 | 67±3 |
Producttype van EV-Zekering
Model | Geschatte Stroom | I2t(A2s) | Machtsdissipatie | Groottecode | |
总 | |||||
MNH3-00-T6A | 6 | 14 | 137 | 1.7 | 0 |
MNH3-00-T10A | 10 | 60 | 280 | 2 | |
MNH3-00-T16A | 16 | 280 | 960 | 3.1 | |
MNH3-00-T20A | 20 | 580 | 2200 | 3.3 | |
MNH3-00-T25A | 25 | 1050 | 3900 | 3.5 | |
MNH3-00-T32A | 32 | 2050 | 5900 | 4.1 | |
MNH3-00-T40A | 40 | 3800 | 9700 | 4.9 | |
MNH3-00-T50A | 50 | 5200 | 13500 | 5.3 | |
MNH3-00-T63A | 63 | 6600 | 20500 | 6.3 | |
MNH3-00-T80A | 80 | 10500 | 30500 | 6.9 | |
MNH3-00-T100A | 100 | 19500 | 59000 | 8.5 | |
MNH3-00-T125A | 125 | 39500 | 119000 | 9.5 | |
MNH3-00-T160A | 160 | 72000 | 192000 | 11.5 | |
Mnh3-1-T80A | 80 | 9900 | 29800 | 7.8 | 1 |
Mnh3-1-T100A | 100 | 19000 | 55000 | 9.6 | |
Mnh3-1-T125A | 125 | 39000 | 11800 | 11.5 | |
Mnh3-1-T160A | 160 | 69000 | 185000 | 12.8 | |
Mnh3-1-T200A | 200 | 119000 | 260000 | 15 | |
Mnh3-1-T224A | 224 | 169000 | 390000 | 17 | |
Mnh3-1-T250A | *250 | 240000 | 498000 | 20 | |
Mnh3-2-T125A | 125 | 39000 | 118000 | 12 | 2 |
Mnh3-2-T160A | 160 | 68000 | 175000 | 13.5 | |
Mnh3-2-T200A | 200 | 99000 | 250000 | 16 | |
Mnh3-2-T224A | 224 | 155000 | 380000 | 17.5 | |
Mnh3-2-T250A | *250 | 220000 | 485000 | 21 | |
Mnh3-2-T300A | 300 | 340000 | 750000 | 24 | |
Mnh3-2-T315A | 315 | 380000 | 860000 | 25 | |
Mnh3-2-T355A | 355 | 525000 | 1170000 | 28 | |
Mnh3-3-T400A | 400 | 720000 | 1550000 | 31 | |
Mnh3-3-T315A | 315 | 380000 | 860000 | 25 | 3 |
Mnh3-3-T355A | 355 | 510000 | 1150000 | 29 | |
Mnh3-3-T400A | *400 | 720000 | 1650000 | 31 | |
Mnh3-3-T425A | 425 | 885000 | 1980000 | 34 | |
Mnh3-3-T500A | *500 | 1240000 | 2950000 | 38 | |
Mnh3-3-T630A | 630 | 1820000 | 5300000 | 44 |
Productomschrijving
Deze reekszekering is geschikt voor AC 50Hz, nominale spanning aan 660V, schatte stroom aan 1000A.lt hoofdzakelijk wordt gebruikt in de elektrische installatie voor het beschermen ircuit tegen overbelasting en kortsluiting (gG/GL); het kan ook voor het beschermen van het halfgeleiderapparaat en anderen volledig vastgesteld voorschot tegen hort-kring (AR) evenals de elektrische motor van kort:sluiten (aM) afleiden. hij schatte brekend vermogen want deze reekszekering aan 120KA.This-reekszekering in overeenstemming is met nationale standaardgb13539 en Internationale elektrocommissie standaardiec60269 is.
Contactpersoon: holly@delfuse.com
Tel.: +8615975669837